Sensing
Technology
Corporation
457-B Boni Avenue New Zaniga Mandaluyong City
Tel No.
532-0088
Fax No.
531-7387
www.heatsenze.com
FX3S
FX3FS
out1 : heating/cooling output
OUT1 : Heating/cooling output
OUT2 : Heating/cooling ouput
- Timer output
- Sensor error detection
alarm output
- Heater defrost output
- Hot gas defrost output
NTC Cooling
Thermostat
Heating Defrost
Digital Temperature Controller
NTC Cooling Defrost 4~20mA RS485 RetransHeating
Digital Temperature Controller
Main-
Function
Input/output
Models
Power Supply
Sensor Spec
Heating/cooling output, precise temperature control, sensor
correction, sensor detection, data backup, min. on/off maintaining
time setup, auto-output operation cycle settable in case of sensor
error
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Relay output : 1point (16A), Temp. sensor input : 1 point (NTC)
DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-55~105°C)
DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50~150°C)
FX3S-00 : Basic model (with DPR-TH1-ET temperature sensor)
FX3D
Main-
Function
Input/output
Models
Power Supply
Sensor Spec
Heating/cooling output, independent timer output, high/low alarm
output, defrost output, precise temperature control, sensor correction,
sensor error detection, data backup, min. on/off maintaining time setup,
RS485 communication (MODBUS), auto-output operation cycle
settable in case of error, transmission output
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Relay output : 1point (16A), Temp. sensor input : 1 point (NTC)
4~20mA Input : 1 point (including power supply)
DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-55~105°C)
DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50~150°C)
FX3S - 00 : Basic model (with DPR-TH1-ET temperature sensor)
FX3D-R4 : Add on Rs485 communication (MODBUS)
FX3D - A4 : Add on 4~20mA transmission output
FX3D - R2 : Add on RS232 communication
FX3D - A1R4 : Add on 4~20mA transmission output,
RS485 communication (MODBUS)
4~20mA
signal input
4~20mA
wiring method
for loop power sensor
Cooling RetransHeatingNTC
Digital Temperature Controller
OUT1 : heang/cooling on/off output
Save : T1 - temperature sensor#1
T2 - temperature sensor#2
1 2
4 5 6 8 9
B1
10
B2COM
FX3FS-00
L2L1
AC100-240V ~
POWER
50/60Hz
NTC
T2T1
OUT
c
16A, 250Vac
Main-
Function
Input/output
Models
Power Supply
Sensor Spec
Heating/cooling output, precise temperature control, sensor correction,
sensor error detection, data back up, min. on/off maintaining time
setup, defrost output, virtual input function, function to prevent
incorrect operation caused by sensor error
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Relay output : 1point (16A), Temp. sensor input : 1 point (NTC)
DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-55~105°C)
DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50~150°C)
FX3S - 00 : Basic model (with 2 pcs ofDPR-TH1-ET temperature sensor)
FX3T
Cooling RS485 RetransHeatingCA(K)
Digital Temperature Controller
n1 n2 n3
n1 : HEAT/COOL #1 ON/OFF output,
alarm output
n2 : HEAT/COOL #2 ON/OFF output,
alarm output
n3 : HEAT/COOL #3 ON/OFF output,
alarm output
Main-
Function
Input/output
Models
Power Supply
Sensor Spec
Heating/cooling output, high/low alarm output, precise temperature
control, sensor correction, sensor error detection, data backup
min. on/off maintaining time setup, transmission output, RS485
communication (MODBUS)
AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Relay output : 3point (10A), Temp. sensor input : 1 point (thermo-couple)
Thermo-couple K type : Measuring range : 0~1000°C
FX3S - 00 : Basic model (with 2 pcs ofDPR-TH1-ET temperature sensor)
DIGITAL TEMPERATURE CONTROLLER
FX Series
SENSETE°CH®
CWC HEAT-EDGE®
RAINBOW
SHIMADEN
PR ELECTRONICS KIMO SEKONIC
HUBA
KAISE
OHKURA CORDEX
FRIED ELECTRIC
DOTECH
V-A1