DX540H
UIC DX540H is a ideal controller for air source heat pump. It is based on microprocessor and
designed with algorithm optimised for air source heat pump. UIC DX540H operates efciently and
manages intensively refrigerant compressor of heat pump. It promotes energy-saving through judge
and control timing of capacity regulation. UIC DX540H is a system to prevent occurrence of
problem by alarming and inform of necessary maintenance.
- Adoption RISC MICOM with high reliability
- Large graphic LCD which can display in Korean, English and Chinese
- Easy to maintain and analyse troubles of equipment by storing 160 trip alarms log
- The best calculation function of defrosting timing by various combination of 8 sources
- Embedded day-timer to enable energy-saving operation
- Easy expansion due to various analog transmission output function
- Alarm function to inform of time to maintain and change expendables through
- Additional state output 4 relays for suction temperature, water temperature,
automatic calculation
evaporation temperature, etc.
Applications
- Air source heat pump
Screen Composition
MENU Composition
Current Temperature
(Inlet/Outlet)
Digital Output State
Operation State
Digital Input State
Lock Signal
Current Time
Temperature,
Operation
Time Info
Equipment State Code
Alarm Message
Heating/Cooling State
Discharge Fault
0820
02
:
24.5
TSUC
TIN
TOUT
TAMB
50.0
24.5
26.0
7.7
DEF 4W PM
OC1 LPS HPSOC2 FSL HCS RET
ID5
C1 C2 SOL
C
MENU SELECT
RUN INFO
OPERATION
SCHEDULE
TRIP LOG
OPERATION
TRIP LOG
00 080102 15:55 INLET FAULT
01 080102 16:10 OUTLET FAULT
02 080102 16:30 OUT AIR FAULT
03 080102 16:30 DISCHARGE FAULT
04 080102 16:45 EVAPO. FAULT
TRIP LOG STATE
LOC STP
X
HEAT SET VALUE : 7.0°C
HEAT SET VALUE : -50.0°C
STEP1 OP DEV. : -2.0°C
STEP2 OP DEV. : -3.0°C
STEP2 STOP DEV : 0.0°C
EVAPO.FAULT 0909102 16:30
STATE : STAND BY
Tsuc. - 40.0 bar Tsp 0.0°C
ID (10~1) :
N (12~1) :
Wiring Diagram (DX540H)
※ Recommended commnunication cables
BELDEN 8761 or 9842
Air-Source Heat Pump Controller
DX Series
SENSETE°CH®
CWC HEAT-EDGE®
RAINBOW
SHIMADEN
PR ELECTRONICS KIMO SEKONIC
HUBA
KAISE
OHKURA CORDEX
FRIED ELECTRIC
DOTECH
V-B11
Sensing
Technology
Corporation
457-B Boni Avenue New Zaniga Mandaluyong City
Tel No.
532-0088
Fax No.
531-7387
www.heatsenze.com
Vista de pagina 12
1 2 ... 8 9 10 11 12 13 14 15

Comentarios a estos manuales

Sin comentarios